ANNISA HANIEFAH, - (2022) PENGEMBANGAN METODE ANALISIS SILIKA QUARTZ DI DALAM SEMEN PORTLAND MENGGUNAKAN SPEKTROFOTOMETRI FOURIER TRANSFORM INFRARED-ATTENUATED TOTAL REFLECTANCE (FTIR-ATR) DENGAN METODE DILUTE AND SHOOT. Skripsi thesis, Sekolah Tinggi Farmasi Indonesia.
Text
S_PSSF_A181006_Title.pdf Download (306kB) |
|
Text
S_PSSF_A181006_Chapter1.pdf Restricted to Repository staff only Download (103kB) |
|
Text
S_PSSF_A181006_Chapter2.pdf Restricted to Repository staff only Download (239kB) |
|
Text
S_PSSF_A181006_Chapter3.pdf Restricted to Repository staff only Download (12kB) |
|
Text
S_PSSF_A181006_Chapter4.pdf Restricted to Repository staff only Download (151kB) |
|
Text
S_PSSF_A181006_Chapter5.pdf Restricted to Repository staff only Download (7kB) |
|
Text
S_PSSF_A181006_Appendix.pdf Restricted to Repository staff only Download (223kB) |
Abstract
Dalam pembuatan semen komponen utamanya berupa oksida kapur (CaO), oksida alumina (Al2O3), oksida besi (Fe2O3) bahkan dijumpai juga silika (SiO2). Pada penelitian ini menggunakan spekrofotometer FTIR-ATR. Tujuan penelitian ini untuk mengukur kadar kristal silika quarts dengan menggunakan metode dilute and shoot kemudian dikuntifikasi dengan alat FTIR-ATR (Spektrofotometri Inframerah Transformasi Fourier-Attenuated Total Reflectance) dari serbuk semen Portland. Parameter pengujian meliputi linearitas, akurasi, presisi, batas deteksi (LOD) dan batas kuantitasi (LOQ). Hasil penelitian menunjukkan hasil uji pada linearitas memiliki koefisien korelasi r = 0,993 dengan batas deteksi dan batas kuantifikasi sebesar 2,97. Uji akurasi memberikan rentang % perolehan kembali 80-110% (nilai recovery konsentrasi 3,75 sekitar 134,75 pada 12,5% sekitar 91,626 dan pada konsentrasi 25% sekitar 80). Uji presisi memiliki rentang 1,6-2,4% (nilai RSD 1,41%). Berdasarkan hasil penelitian dapat disimpulkan bahwa Spektrofotometri FTIR-ATR pada uji silika dengan semen menggunakan metode Dilute and Shoot belum tervalidasi dan belum memenuhi kriteria dari parameter validasinya. --- In the cement production, the main component are oxidized silica (SiO2), lime oxide (CaO), alumina oxide (Al2O3) and iron oxide (Fe2O3). In this study, the FTIR-ATR Spectrophotometer was use to identify and quantitate silica. The objective of this study was to evaluate the crystalline silika quarts using the dilute and shoot method using the FTIR-ATR (Fourier Transform Infrared Spectrophotometry) from Portland cement powder. Test parameters include linearity, accuracy, precision, limit of detection (LOD) and limit quantitation (LOQ). The result showed that the linearity has good correlation coefficient 0.993, recovery percentage at 80% - 134% The precision test at 1,6-2,4%. Based on the result of the study, the FTIRATR spectrophotometry on the silica-cement test with dilute and shoot
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | validasi metode, semen portland, silika (SiO2) --- method validation, portland cement, silica (SiO2) |